Dataplace Arnhem

Dataplace Arnhem is a carrier-neutral, energy-efficient Tier III datacenter which is configured for full redundancy and which meets the highest availability and security requirements.

Dataplace Arnhem became part of Dataplace in 2017, it has a track record of 100% uptime stretching back more than 20 years.

As our services are targeted mainly at businesses and organisations in the east of the Netherlands as well as Germany, the datacenter has an easily accessible location at Tivolilaan 251 in Arnhem. Easily reachable from the motorway and with ample free parking around the datacenter.

Configuration

The datacenter is fully configured for maximum ease of installation and maintenance of your IT infrastructure. There is a car park close to the building with sufficient free parking at all times, enabling you to carry out maintenance on your servers whenever it suits you. A goods entrance is available which you can use free of charge to load and unload your equipment. In addition, our internal lift can be used to move your equipment to the 1st floor without difficulty. The entire premises are barrier-free and without thresholds, and trolleys are provided for moving your equipment and tools with ease. A dedicated customer area is also provided for you to work in, and there is a meeting room which can be booked quickly and easily online.

General specifications

Total gross floor area
1,000 m2

Total net datacenter space
570 m2

Tier Classification
Tier 3

Access control
24/7 independent access by means of access badge and numeric code

Floor load
1,000 kg/m2

Parking spaces
6

Technical specifications

Power supply
2N

kW available per rack
minimum 5kW

Autonomy back-up generators
Minimum 24 hours (without refuelling)

Power feed per full 19" rack
2 x 25 Ampère No-Break

Cooling
N+1

Cooling provided by
dry cooling / chillers with free cooling

Cold corridors
Yes

Security

Dataplace Arnhem is well equipped with security measures and meets the highest standards of security certification. In addition to ISO 9001, ISO 14001, ISO 27001 and ISO 50001 certification, the datacenter also has NEN 7510 and ISAE-3402 type 2 certification. The site is secured with fencing and access is provided via a turnstile and sliding gate. The entire fencing also incorporates a power fence. An intrusion and access control system with CCTV surveillance provides overall on-site security.

Fire prevention

Both data floors are fitted with a fire-detection system in combination with Very Early Smoke Detection Alarms (VESDA) systems, which detect dust and soot particles. In the unlikely event of a fire, a gas extinguishing system will lower the oxygen concentration to a level that ensures the fire is quickly put out. The system uses Argonite: a mixture of Argon and nitrogen. This mixture of gases is stored under high pressure and is automatically released into the area in the event of fire. Unlike a water-based extinguishing system, this method of fire control does not damage your equipment.